Probes
- 100 MHz, 200 MHz models
- TPP0250, 250 MHz bandwidth, 10X, 3.9 pF. One passive voltage probe per analog channel
- 350 MHz, 500 MHz models
- TPP0500B, 500 MHz bandwidth, 10X, 3.9 pF. One passive voltage probe per analog channel
- 1 GHz models
- TPP1000, 1 GHz bandwidth, 10X, 3.9 pF. One passive voltage probe per analog channel
- Any model with MDO3MSO option
- One P6316 16-channel logic probe and accessories
ACCESSORIES
- 103-0473-00
- N-to-BNC adapter
- 063-4526-xx
- Documentation CD
- 071-3249-00
- Installation and Safety Instructions, printed manual (translated in English, Japanese, and Simplified Chinese)
- 016-2008-xx
- Accessory bag
- -
- Power cord
- -
- OpenChoice® Desktop Software (available on the Documentation CD and for download from www.tektronix.com/downloads.)
- -
- Calibration certificate documenting traceability to National Metrology Institute(s) and ISO9001 quality system registration
WARRANTY
Three-year warranty covering all parts and labor, excluding probes.
Step 2: Configure your MDO3000 by adding instrument options
Instrument options
All MDO3000 Series instruments can be preconfigured from the factory with the following options:
- MDO3AFG
- Arbitrary function generator with 13 predefined waveforms and arbitrary waveform generation
- MDO3MSO
- 16 digital channels; includes P6316 digital probe and accessories
- MDO3SA
- Increase spectrum analyzer input frequency range to 9 kHz – 3 GHz and capture bandwidth to 3 GHz.
- MDO3SEC
- Enhanced instrument security to enable password protected control of turning on/off all instrument ports and instrument firmware update functionality.
POWER CORD AND PLUG OPTIONS
- Opt. A0
- North America power plug (115 V, 60 Hz)
- Opt. A1
- Universal Euro power plug (220 V, 50 Hz)
- Opt. A2
- United Kingdom power plug (240 V, 50 Hz)
- Opt. A3
- Australia power plug (240 V, 50 Hz)
- Opt. A5
- Switzerland power plug (220 V, 50 Hz)
- Opt. A6
- Japan power plug (100 V, 110/120 V, 60 Hz)
- Opt. A10
- China power plug (50 Hz)
- Opt. A11
- India power plug (50 Hz)
- Opt. A12
- Brazil power plug (60 Hz)
- Opt. A99
- No power cord
LANGUAGE OPTIONS
All products are shipped with an Installation and Safety manual that is in English, Japanese, and Simplified Chinese. Full user manuals translated in each language listed below are included with each product in pdf format on the Documentation CD.
- Opt. L0
- English front panel label
- Opt. L1
- French front panel overlay
- Opt. L2
- Italian front panel overlay
- Opt. L3
- German front panel overlay
- Opt. L4
- Spanish front panel overlay
- Opt. L5
- Japanese front panel overlay
- Opt. L6
- Portuguese front panel overlay
- Opt. L7
- Simplified Chinese front panel overlay
- Opt. L8
- Traditional Chinese front panel overlay
- Opt. L9
- Korean front panel overlay
- Opt. L10
- Russian front panel overlay
- Opt. L99
- No manual, English front panel label
SERVICE OPTIONS
- Opt. C3
- Calibration Service 3 Years
- Opt. C5
- Calibration Service 5 Years
- Opt. D1
- Calibration Data Report
- Opt. D3
- Calibration Data Report 3 Years (with Opt. C3)
- Opt. D5
- Calibration Data Report 5 Years (with Opt. C5)
- Opt. G3
- Complete Care 3 Years (includes loaner, scheduled calibration, and more)
- Opt. G5
- Complete Care 5 Years (includes loaner, scheduled calibration, and more)
- Opt. R5
- Repair Service 5 Years (including warranty)
Probes and accessories are not covered by the oscilloscope warranty and service offerings. Refer to the datasheet of each probe and accessory model for its unique warranty and calibration terms.
STEP 3: SELECT APPLICATION MODELS AND ACCESSORIES
- Application modules
- Application modules are purchased as stand-alone products and can be purchased at the time of initial MDO3000 purchase or at any future time.
Application modules have licenses which can be transferred between an application module and an oscilloscope. The license may be contained in the module; allowing the module to be moved from one instrument to another. Or, the license can be contained in the oscilloscope; allowing the module to be removed and stored for safekeeping. The license can be transferred back to the module for use in another MDO3000 oscilloscope. Transferring the license to an oscilloscope and removing the module permits the use of more than two applications simultaneously.
- MDO3AERO
- Aerospace Serial Triggering and Analysis Module. Enables triggering on packet-level information on MIL-STD-1553 buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time- stamp information.
Signal Inputs - Any Ch1 - Ch4, Math, Ref1 - Ref4
Recommended Probing - Differential or single ended (only one single-ended signal required)
- MDO3AUDIO
- Audio Serial Triggering and Analysis Module. Enables triggering on packet-level information on I2S, LJ, RJ, and TDM audio buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time-stamp information.
Signal Inputs - Any Ch1 - Ch4, any D0 - D15
Recommended Probing - Single ended
- MDO3AUTO
- Automotive Serial Triggering and Analysis Module. Enables triggering on packet-level information on CAN and LIN buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time- stamp information.
Signal Inputs – CAN or LIN: Any Ch1 - Ch4, any D0 - D15
Recommended Probing - CAN: Single ended or differential; LIN: Single ended
- MDO3COMP
- Computer Serial Triggering and Analysis Module. Enables triggering on packet-level information on RS-232/422/485/UART buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time-stamp information.
Signal Inputs - Any Ch1 - Ch4, any D0 - D15
Recommended Probing - RS-232/UART: Single ended; RS-422/485: Differential
- MDO3EMBD
- Embedded Serial Triggering and Analysis Module. Enables triggering on packet-level information on I2C and SPI buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time- stamp information.
Signal Inputs - I2C or SPI: Any Ch1 - Ch4, any D0 - D15
Recommended Probing - Single ended
- MDO3FLEX
-
FlexRay Serial Triggering and Analysis Module. Enables triggering on packet-level information on FlexRay buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, packet decode tables with time-stamp information.
Signal Inputs - Any Ch1 - Ch4 (and any D0 - D15 when MDO3MSO option is installed; single-ended probing only)
Recommended Probing - Single ended or differential
- MDO3USB
- USB Serial Triggering and Analysis Module. Enables triggering on packet-level content for low-speed, and full-speed USB serial buses. Also enables analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time-stamp information for low-speed, full-speed, and high-speed USB serial buses.
Signal Inputs - Low-speed and Full-speed: Any Ch1 - Ch4, any D0 - D15; Low-speed, Full-speed, and High-speed: Any Ch1 - Ch4, Math, Ref1 - Ref4
Note: High-speed decode support only available on 1 GHz models.
Recommended Probing - Low-speed and Full-speed: Single ended or differential; High-speed: Differential
- MDO3PWR
- Power Analysis Application Module. Enables quick and accurate analysis of power quality, switching loss, harmonics, safe operating area (SOA), modulation, ripple, and slew rate (dI/dt, dV/dt).
- MDO3LMT
- Limit and Mask Testing Application Module. Enables testing against limit templates generated from "golden" waveforms and mask testing using custom masks.
RECOMMENDED ACCESSORIES
Probes
Tektronix offers over 100 different probes to meet your application needs. For a comprehensive listing of available probes, please visit www.tektronix.com/probes.
- TPP0250
- 250 MHz, 10X TekVPI® passive voltage probe with 3.9 pF input capacitance
- TPP0500B
- 500 MHz, 10X TekVPI® passive voltage probe with 3.9 pF input capacitance
- TPP0502
- 500 MHz, 2X TekVPI® passive voltage probe with 12.7 pF input capacitance
- TPP0850
- 2.5 kV, 800 MHz, 50X TekVPI® passive high-voltage probe
- TPP1000
- 1 GHz, 10X TekVPI® passive voltage probe with 3.9 pF input capacitance
- TAP1500
- 1.5 GHz TekVPI® active single-ended voltage probe
- TAP2500
- 2.5 GHz TekVPI® active single-ended voltage probe
- TAP3500
- 3.5 GHz TekVPI® active single-ended voltage probe
- TCP0020
- 50 MHz TekVPI® 20 Ampere AC/DC current probe
- TCP0030A
- 120 MHz TekVPI® 30 Ampere AC/DC current probe
- TCP0150
- 20 MHz TekVPI® 150 Ampere AC/DC current probe
- TDP0500
- 500 MHz TekVPI® differential voltage probe with ±42 V differential input voltage
- TDP1000
- 1 GHz TekVPI® differential voltage probe with ±42 V differential input voltage
- TDP1500
- 1.5 GHz TekVPI® differential voltage probe with ±8.5 V differential input voltage
- TDP3500
- 3.5 GHz TekVPI® differential voltage probe with ±2 V differential input voltage
- THDP0200
- ±1.5 kV, 200 MHz TekVPI® high-voltage differential probe
- THDP0100
- ±6 kV, 100 MHz TekVPI® high-voltage differential probe
- TMDP0200
- ±750 V, 200 MHz TekVPI® high-voltage differential probe
ACCESSORIES
- TPA-N-PRE
- Preamplifier, 12 dB nominal Gain, 9 kHz - 6 GHz
- TPA-N-VPI
- N-to-TekVPI adapter
- 119-4146-00
- Near field probe set, 100 kHz - 1 GHz
- 119-6609-00
- Flexible monopole antenna
- 077-0981-xx
- Service manual (English only)
- TPA-BNC
- TekVPI® to TekProbe™ BNC adapter
- TEK-DPG
- TekVPI Deskew pulse generator signal source
- 067-1686-xx
- Power measurement deskew and calibration fixture
- SignalVu-PC-SVE
- Vector Signal Analysis Software
- TEK-USB-488
- GPIB-to-USB adapter
- ACD3000
- Soft transit case (includes front protective cover)
- HCTEK54
- Hard transit case (requires ACD3000)
- RMD3000
- Rackmount kit
- 200-5052-00
- Front protective cover
OTHER RF PROBES
Contact Beehive Electronics to order: http://beehive-electronics.com/probes.html
- 101A
- EMC probe set
- 150A
- EMC probe amplifier
- 110A
- Probe cable
- 0309-0001
- SMA probe adapter
- 0309-0006
- BNC probe adapter
STEP 4: ADD INSTRUMENT UPGRADES IN THE FUTURE
Instrument upgrades
The MDO3000 Series products offer a number of ways to add functionality after the initial purchase. Listed below are the various product upgrades available and the method of upgrade used for each product.
- Post-purchase instrument options
- The following products are sold as stand-alone products and can be purchased at any time to add functionality to any MDO3000 product.
- MDO3AFG
- Add arbitrary function generator to any MDO3000 Series product.
One-time, permanent upgrade to any model enabled through single-use application module hardware key. The hardware key is used to enable the feature and then is not required for future use.
- MDO3MSO
- Add 16 digital channels; includes P6316 digital probe and accessories .
One-time, permanent upgrade to any model enabled through single-use application module hardware key. The hardware key is used to enable the feature and then is not required for future use.
- MDO3SA
- Increase spectrum analyzer input frequency range to 9 kHz – 3 GHz and capture bandwidth to 3 GHz.
One-time, permanent upgrade to any model enabled through single-use application module hardware key. The hardware key is used to enable the feature and then is not required for future use.
- MDO3SEC
- Add enhanced instrument security to enable password protected control of turning on/off all instrument ports and instrument firmware update functionality.
One-time, permanent upgrade to any model enabled through software option key. Software option key products require that the instrument model and serial number be provided at the time of purchase. The software option key is specific to the model and serial number combination.
- Bandwidth upgrade options
- Instrument bandwidth can be upgraded on any MDO3000 Series product after initial purchase. Each upgrade product will increase the analog bandwidth and the spectrum analyzer frequency range to the new bandwidth level. Bandwidth upgrades are purchased based on the combination of the current bandwidth and the desired bandwidth. Software option key products require that the instrument model and serial number be provided at the time of purchase. The software option key is specific to the model and serial number combination. Bandwidth upgrades up to 500 MHz can be performed in the field. Bandwidth upgrades to 1 GHz require installation at a Tektronix service center. The table below shows the various bandwidth upgrade products to purchase based on current and desired bandwidth levels. </
Model to be upgraded |
Bandwidth before upgrade |
Bandwidth after upgrade |
Order protduct |
MDO3012 |
100 MHz |
200 MHz |
MDO3BW1T22 |
100 MHz |
350 MHz |
MDO3BW1T32 |
100 MHz |
500 MHz |
MDO3BW1T52 |
100 MHz |
1 GHz |
MDO3BW1T102 |
200 MHz |
350 MHz |
MDO3BW2T32 |
200 MHz |
500 MHz |
MDO3BW2T52 |
200 MHz |
1 GHz |
MDO3BW2T102 |
350 MHz |
500 MHz |
MDO3BW3T52 |
350 MHz |
1 GHz |
MDO3BW3T102 |
500 MHz |
1 GHz |
MDO3BW5T102 |
MDO3014 |
100 MHz |
200 MHz |
MDO3BW1T24 |
100 MHz |
350 MHz |
MDO3BW1T34 |
100 MHz |
500 MHz |
MDO3BW1T54 |
100 MHz |
1 GHz |
MDO3BW1T104 |
200 MHz |
350 MHz |
MDO3BW2T34 |
200 MHz |
500 MHz |
MDO3BW2T54 |
200 MHz |
1 GHz |
MDO3BW2T104 |
350 MHz |
500 MHz |
MDO3BW3T54 |
350 MHz |
1 GHz |
MDO3BW3T104 |
500 MHz |
1 GHz |
MDO3BW5T104 |
MDO3022 |
200 MHz |
350 MHz |
MDO3BW2T32 |
200 MHz |
500 MHz |
MDO3BW2T52 |