Probes
100 MHz, 200 MHz models
TPP0250, 250 MHz bandwidth, 10X, 3.9 pF. One passive voltage probe per analog channel
350 MHz, 500 MHz models
TPP0500B, 500 MHz bandwidth, 10X, 3.9 pF. One passive voltage probe per analog channel
1 GHz models
TPP1000, 1 GHz bandwidth, 10X, 3.9 pF. One passive voltage probe per analog channel
Any model with MDO3MSO option
One P6316 16-channel logic probe and accessories
ACCESSORIES
103-0473-00 
N-to-BNC adapter
063-4526-xx
Documentation CD
071-3249-00 
Installation and Safety Instructions, printed manual (translated in English, Japanese, and Simplified Chinese)
016-2008-xx
Accessory bag
-
Power cord
-
OpenChoice® Desktop Software (available on the Documentation CD and for download from www.tektronix.com/downloads.)
-
Calibration certificate documenting traceability to National Metrology Institute(s) and ISO9001 quality system registration
WARRANTY
Three-year warranty covering all parts and labor, excluding probes.
Step 2: Configure your MDO3000 by adding instrument options
Instrument options

All MDO3000 Series instruments can be preconfigured from the factory with the following options:

MDO3AFG
Arbitrary function generator with 13 predefined waveforms and arbitrary waveform generation
MDO3MSO
16 digital channels; includes P6316 digital probe and accessories
MDO3SA
Increase spectrum analyzer input frequency range to 9 kHz – 3 GHz and capture bandwidth to 3 GHz.
MDO3SEC
Enhanced instrument security to enable password protected control of turning on/off all instrument ports and instrument firmware update functionality.
POWER CORD AND PLUG OPTIONS
Opt. A0
North America power plug (115 V, 60 Hz)
Opt. A1
Universal Euro power plug (220 V, 50 Hz)
Opt. A2
United Kingdom power plug (240 V, 50 Hz)
Opt. A3
Australia power plug (240 V, 50 Hz)
Opt. A5
Switzerland power plug (220 V, 50 Hz)
Opt. A6
Japan power plug (100 V, 110/120 V, 60 Hz)
Opt. A10
China power plug (50 Hz)
Opt. A11
India power plug (50 Hz)
Opt. A12
Brazil power plug (60 Hz)
Opt. A99
No power cord
LANGUAGE OPTIONS

All products are shipped with an Installation and Safety manual that is in English, Japanese, and Simplified Chinese. Full user manuals translated in each language listed below are included with each product in pdf format on the Documentation CD.

Opt. L0
English front panel label
Opt. L1
French front panel overlay
Opt. L2
Italian front panel overlay
Opt. L3
German front panel overlay
Opt. L4
Spanish front panel overlay
Opt. L5
Japanese front panel overlay
Opt. L6
Portuguese front panel overlay
Opt. L7
Simplified Chinese front panel overlay
Opt. L8
Traditional Chinese front panel overlay
Opt. L9
Korean front panel overlay
Opt. L10
Russian front panel overlay
Opt. L99
No manual, English front panel label
SERVICE OPTIONS
Opt. C3
Calibration Service 3 Years
Opt. C5
Calibration Service 5 Years
Opt. D1
Calibration Data Report
Opt. D3
Calibration Data Report 3 Years (with Opt. C3)
Opt. D5
Calibration Data Report 5 Years (with Opt. C5)
Opt. G3
Complete Care 3 Years (includes loaner, scheduled calibration, and more)
Opt. G5
Complete Care 5 Years (includes loaner, scheduled calibration, and more)
Opt. R5
Repair Service 5 Years (including warranty)

Probes and accessories are not covered by the oscilloscope warranty and service offerings. Refer to the datasheet of each probe and accessory model for its unique warranty and calibration terms.

STEP 3: SELECT APPLICATION MODELS AND ACCESSORIES
Application modules
Application modules are purchased as stand-alone products and can be purchased at the time of initial MDO3000 purchase or at any future time.

Application modules have licenses which can be transferred between an application module and an oscilloscope. The license may be contained in the module; allowing the module to be moved from one instrument to another. Or, the license can be contained in the oscilloscope; allowing the module to be removed and stored for safekeeping. The license can be transferred back to the module for use in another MDO3000 oscilloscope. Transferring the license to an oscilloscope and removing the module permits the use of more than two applications simultaneously.

MDO3AERO
Aerospace Serial Triggering and Analysis Module. Enables triggering on packet-level information on MIL-STD-1553 buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time- stamp information.

Signal Inputs - Any Ch1 - Ch4, Math, Ref1 - Ref4

Recommended Probing - Differential or single ended (only one single-ended signal required)

MDO3AUDIO
Audio Serial Triggering and Analysis Module. Enables triggering on packet-level information on I2S, LJ, RJ, and TDM audio buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time-stamp information.

Signal Inputs - Any Ch1 - Ch4, any D0 - D15

Recommended Probing - Single ended

MDO3AUTO
Automotive Serial Triggering and Analysis Module. Enables triggering on packet-level information on CAN and LIN buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time- stamp information.

Signal Inputs – CAN or LIN: Any Ch1 - Ch4, any D0 - D15

Recommended Probing - CAN: Single ended or differential; LIN: Single ended

MDO3COMP
Computer Serial Triggering and Analysis Module. Enables triggering on packet-level information on RS-232/422/485/UART buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time-stamp information.

Signal Inputs - Any Ch1 - Ch4, any D0 - D15

Recommended Probing - RS-232/UART: Single ended; RS-422/485: Differential

MDO3EMBD
Embedded Serial Triggering and Analysis Module. Enables triggering on packet-level information on I2C and SPI buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time- stamp information.

Signal Inputs - I2C or SPI: Any Ch1 - Ch4, any D0 - D15

Recommended Probing - Single ended

MDO3FLEX

FlexRay Serial Triggering and Analysis Module. Enables triggering on packet-level information on FlexRay buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, packet decode tables with time-stamp information.

Signal Inputs - Any Ch1 - Ch4 (and any D0 - D15 when MDO3MSO option is installed; single-ended probing only)

Recommended Probing - Single ended or differential

MDO3USB
USB Serial Triggering and Analysis Module. Enables triggering on packet-level content for low-speed, and full-speed USB serial buses. Also enables analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time-stamp information for low-speed, full-speed, and high-speed USB serial buses.

Signal Inputs - Low-speed and Full-speed: Any Ch1 - Ch4, any D0 - D15; Low-speed, Full-speed, and High-speed: Any Ch1 - Ch4, Math, Ref1 - Ref4

Note: High-speed decode support only available on 1 GHz models.

Recommended Probing - Low-speed and Full-speed: Single ended or differential; High-speed: Differential

MDO3PWR
Power Analysis Application Module. Enables quick and accurate analysis of power quality, switching loss, harmonics, safe operating area (SOA), modulation, ripple, and slew rate (dI/dt, dV/dt).
MDO3LMT
Limit and Mask Testing Application Module. Enables testing against limit templates generated from "golden" waveforms and mask testing using custom masks.
RECOMMENDED ACCESSORIES
Probes

Tektronix offers over 100 different probes to meet your application needs. For a comprehensive listing of available probes, please visit www.tektronix.com/probes.

TPP0250
250 MHz, 10X TekVPI® passive voltage probe with 3.9 pF input capacitance
TPP0500B
500 MHz, 10X TekVPI® passive voltage probe with 3.9 pF input capacitance
TPP0502
500 MHz, 2X TekVPI® passive voltage probe with 12.7 pF input capacitance
TPP0850
2.5 kV, 800 MHz, 50X TekVPI® passive high-voltage probe
TPP1000
1 GHz, 10X TekVPI® passive voltage probe with 3.9 pF input capacitance
TAP1500
1.5 GHz TekVPI® active single-ended voltage probe
TAP2500
2.5 GHz TekVPI® active single-ended voltage probe
TAP3500
3.5 GHz TekVPI® active single-ended voltage probe
TCP0020
50 MHz TekVPI® 20 Ampere AC/DC current probe
TCP0030A
120 MHz TekVPI® 30 Ampere AC/DC current probe
TCP0150
20 MHz TekVPI® 150 Ampere AC/DC current probe
TDP0500
500 MHz TekVPI® differential voltage probe with ±42 V differential input voltage
TDP1000
1 GHz TekVPI® differential voltage probe with ±42 V differential input voltage
TDP1500
1.5 GHz TekVPI® differential voltage probe with ±8.5 V differential input voltage
TDP3500
3.5 GHz TekVPI® differential voltage probe with ±2 V differential input voltage
THDP0200
±1.5 kV, 200 MHz TekVPI® high-voltage differential probe
THDP0100
±6 kV, 100 MHz TekVPI® high-voltage differential probe
TMDP0200
±750 V, 200 MHz TekVPI® high-voltage differential probe
ACCESSORIES
TPA-N-PRE
Preamplifier, 12 dB nominal Gain, 9 kHz - 6 GHz
TPA-N-VPI
N-to-TekVPI adapter
119-4146-00 
Near field probe set, 100 kHz - 1 GHz
119-6609-00 
Flexible monopole antenna
077-0981-xx
Service manual (English only)
TPA-BNC
TekVPI® to TekProbe™ BNC adapter
TEK-DPG
TekVPI Deskew pulse generator signal source
067-1686-xx
Power measurement deskew and calibration fixture
SignalVu-PC-SVE
Vector Signal Analysis Software
TEK-USB-488 
GPIB-to-USB adapter
ACD3000
Soft transit case (includes front protective cover)
HCTEK54
Hard transit case (requires ACD3000)
RMD3000
Rackmount kit
200-5052-00 
Front protective cover
OTHER RF PROBES

Contact Beehive Electronics to order: http://beehive-electronics.com/probes.html

101A
EMC probe set
150A
EMC probe amplifier
110A
Probe cable
0309-0001 
SMA probe adapter
0309-0006 
BNC probe adapter
STEP 4: ADD INSTRUMENT UPGRADES IN THE FUTURE
Instrument upgrades

The MDO3000 Series products offer a number of ways to add functionality after the initial purchase. Listed below are the various product upgrades available and the method of upgrade used for each product.

Post-purchase instrument options
The following products are sold as stand-alone products and can be purchased at any time to add functionality to any MDO3000 product.
MDO3AFG
Add arbitrary function generator to any MDO3000 Series product.

One-time, permanent upgrade to any model enabled through single-use application module hardware key. The hardware key is used to enable the feature and then is not required for future use.

MDO3MSO
Add 16 digital channels; includes P6316 digital probe and accessories .

One-time, permanent upgrade to any model enabled through single-use application module hardware key. The hardware key is used to enable the feature and then is not required for future use.

MDO3SA
Increase spectrum analyzer input frequency range to 9 kHz – 3 GHz and capture bandwidth to 3 GHz.

One-time, permanent upgrade to any model enabled through single-use application module hardware key. The hardware key is used to enable the feature and then is not required for future use.

MDO3SEC
Add enhanced instrument security to enable password protected control of turning on/off all instrument ports and instrument firmware update functionality.

One-time, permanent upgrade to any model enabled through software option key. Software option key products require that the instrument model and serial number be provided at the time of purchase. The software option key is specific to the model and serial number combination.

Bandwidth upgrade options
Instrument bandwidth can be upgraded on any MDO3000 Series product after initial purchase. Each upgrade product will increase the analog bandwidth and the spectrum analyzer frequency range to the new bandwidth level. Bandwidth upgrades are purchased based on the combination of the current bandwidth and the desired bandwidth. Software option key products require that the instrument model and serial number be provided at the time of purchase. The software option key is specific to the model and serial number combination. Bandwidth upgrades up to 500 MHz can be performed in the field. Bandwidth upgrades to 1 GHz require installation at a Tektronix service center. The table below shows the various bandwidth upgrade products to purchase based on current and desired bandwidth levels. </
Model to be upgraded Bandwidth before upgrade Bandwidth after upgrade Order protduct
MDO3012 100 MHz 200 MHz MDO3BW1T22
100 MHz 350 MHz MDO3BW1T32
100 MHz 500 MHz MDO3BW1T52
100 MHz 1 GHz MDO3BW1T102
200 MHz 350 MHz MDO3BW2T32
200 MHz 500 MHz MDO3BW2T52
200 MHz 1 GHz MDO3BW2T102
350 MHz 500 MHz MDO3BW3T52
350 MHz 1 GHz MDO3BW3T102
500 MHz 1 GHz MDO3BW5T102
MDO3014 100 MHz 200 MHz MDO3BW1T24
100 MHz 350 MHz MDO3BW1T34
100 MHz 500 MHz MDO3BW1T54
100 MHz 1 GHz MDO3BW1T104
200 MHz 350 MHz MDO3BW2T34
200 MHz 500 MHz MDO3BW2T54
200 MHz 1 GHz MDO3BW2T104
350 MHz 500 MHz MDO3BW3T54
350 MHz 1 GHz MDO3BW3T104
500 MHz 1 GHz MDO3BW5T104
MDO3022 200 MHz 350 MHz MDO3BW2T32
200 MHz 500 MHz MDO3BW2T52